Instruction Packet Instruction = WRITE_DATA, Address = 0x2F, DATA = 0x01
Communication ->[Dynamixel]:FF FF 00 04 03 2F 01
C8 (LEN:008)
<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)
Status Packet Result NO ERROR
If Locked, it can only be unlocked by removing power.
If trying to access other data areas whilst locked, an error will be returned.
->[Dynamixel]:FF FF 00 05 03 30 40 00 87 (LEN:009)
<-[Dynamixel]:FF FF 00 02 08 F5 (LEN:006)
Example 20 Set the minimum punch (output) in the Dynamixel with ID=0 to 0x40.
Instruction Packet Instruction = WRITE_DATA, Address = 0x30, DATA = 0x40, 0x00
Communication ->[Dynamixel]:FF FF 00 05 03 30 40 00
87 (LEN:009)
<-[Dynamixel]:FF FF 00 02 00 FD (LEN:006)
Status Packet Result NO ERROR
Range Error